Zhiwai details how Schneider Electric’s AirSeT meets SF6-free switchgear specs

Oct. 27, 2026
By AI, Created 22:43 UTC, Oct 27, 2026, AGP -

Zhiwai has published a guide on Schneider Electric AirSeT’s Pure Air insulation and vacuum interruption for medium-voltage buyers in Singapore and Malaysia. The report explains how procurement teams can specify fluorinated-gas-free switchgear, assess end-of-life handling and check compliance with EU rules and IEC test evidence.

Why it matters: - The guide gives buyers a clearer way to specify medium-voltage switchgear that excludes sulfur hexafluoride and other fluorinated gases. - Procurement teams in Singapore and Malaysia can use the guide to connect gas composition, equipment design, tender language and end-of-life handling. - The guide also helps buyers distinguish between an SF₆-free label and a truly fluorinated-gas-free design.

What happened: - Zhiwai released a guide examining Schneider Electric AirSeT™ and how the platform addresses medium-voltage procurement requirements that exclude SF₆ and other fluorinated gases. - The guide focuses on buyers in Singapore and Malaysia. - The report draws on manufacturer documentation and regulatory texts, and it does not include independent product testing.

The details: - Schneider Electric’s Pure Air uses filtered, purified and pressurized air made mainly of nitrogen and oxygen, without fluorinated additives. - AirSeT combines Pure Air insulation with vacuum interruption, which removes the need for F-gases in those functions. - Schneider Electric states a global warming potential of zero for Pure Air. - That GWP figure describes the insulating medium, not the full equipment lifecycle emissions. - In SM AirSeT, a modular secondary-distribution range up to 24 kV, Pure Air provides insulation and Shunt Vacuum Interruption™ handles load-current interruption. - As the disconnector opens, current is diverted through a vacuum interrupter. - The design separates insulation and interruption while keeping a compact switching arrangement. - Circuit-breaker functions use vacuum circuit breakers for fault-current interruption. - RM AirSeT applies Pure Air insulation and SVI to gas-insulated secondary switchgear and ring main units. - RM AirSeT retains the familiar closed, open and earthed switch positions. - GM AirSeT Performance uses Pure Air insulation with vacuum circuit-breaker technology for primary distribution. - These product ranges serve different distribution duties, so configuration and electrical ratings remain key selection criteria. - AirSeT’s Pure Air approach removes the need to recover or recycle fluorinated gas from the insulating medium at end of life. - Retirement planning still requires electrical isolation, controlled depressurization where applicable, dismantling and component recycling. - When AirSeT replaces existing SF₆ equipment, gas recovery from the retired equipment remains a separate responsibility. - Some SF₆-free technologies use fluorinated mixtures with low GWP. - The European Commission’s switchgear FAQ identifies C5 fluoroketone and C4 fluoronitrile among the relevant regulated gases. - A low-mixture GWP does not make those constituents non-fluorinated. - AirSeT’s Pure Air route excludes those additives. - Under Article 13(9) of Regulation (EU) 2024/573, putting MV switchgear using fluorinated greenhouse gases into operation is prohibited, subject to specified derogations, from January 1, 2026, up to and including 24 kV. - The same rule applies from January 1, 2030, above 24 kV and up to and including 52 kV. - The EU rules do not create a general exemption for mixtures with GWP below one. - The EU provisions do not themselves create a local prohibition in Singapore or Malaysia.

Between the lines: - The guide is aimed at procurement teams that want a spec-based path to verify what kind of insulating and interrupting media a bidder is offering. - The emphasis on composition declarations and handling instructions suggests that labels alone are not enough for acceptance decisions. - The guide also signals that buyers should separate global regulatory context from local procurement obligations and corporate policy.

What's next: - Buyers should state in tenders that fluorinated gases are excluded for both insulation and current interruption. - For an AirSeT offer, buyers should request the declared air composition, the interruption technology and the handling instructions for the exact configuration. - Buyers should also request the applicable IEC 62271 type-test documentation and confirm voltage, current, short-circuit ratings and site conditions. - IEC 63360:2025 covers alternative-gas quality and analysis before filling, but it does not replace equipment performance evidence. - Zhiwai says its guide is intended to help engineers, buyers and network operators evaluate document-based product claims.

The bottom line: - Zhiwai’s guide says the most reliable way to specify SF₆-free switchgear is to define the insulating medium, the interruption technology and the required test evidence in the tender itself.

Disclaimer: This article was produced by AGP Wire with the assistance of artificial intelligence based on original source content and has been refined to improve clarity, structure, and readability. This content is provided on an “as is” basis. While care has been taken in its preparation, it may contain inaccuracies or omissions, and readers should consult the original source and independently verify key information where appropriate. This content is for informational purposes only and does not constitute legal, financial, investment, or other professional advice.

Sign up for:

European Jobs Online

The daily local news briefing you can trust. Every day. Subscribe now.

By signing up, you agree to our Terms & Conditions.

Share this page:

Advanced Search Options

Search for:

Search scope:

Type:

Search in:

Date range:

The last

Sort by:

Sign up for:

European Jobs Online

The daily local news briefing you can trust. Every day. Subscribe now.

By signing up, you agree to our Terms & Conditions.